Installation
Location
• Locate the autocast universal
®
230 in a clean dry room.
• Ensure that the room is sufficiently spacious
• Do not position the autocast universal
®
230 close to ovens or
other heat generating devices
• The autocast universal
®
230 is a bench unit.
Bench height, 85–90 cm /33
1
⁄2 –35
1
⁄2”.
• Ensure that the bench is sufficiently stable and does not
wobble (minimum carrying capacity 100 kg/220 lbs.)
• The distance between the wall of the room and the back
panel of the machine should be approximately 20 cm/8”.
• Align the unit by using a spirit level and the adjustable legs.
• Ensure that the working area is well illuminated.
Electrical connection
The unit is connected to the power supply via a grounded
safety socket. Distance from unit is 1 metre.
Connected load: 230 V, 3-phase, 50-60 Hz,
4,6 kVA
Cable length: 2 m
Socket: protected by 1 x16 A slow acting
Neozed fuse
Argon supply
Use only argon of the following classification:
Argon 4.8 HR 99.998% to DIN 32526 or higher purity
Size of argon cylinder: 10 litres min.
• Secure the argon cylinder with a chain to prevent it from
falling over
• the argon cylinder at a maximum distance of 1 metre from
the machine
• Connect the pressure regulator to the argon cylinder using
an open ended wrench
Push the argon hose onto the coupling (argon) in the back
panel of the unit and connect the other end to the pressure
regulator using a hose clamp.
Always make sure that the valve at the gas bottle
is opened and that there is enough gas in the gas
container.
autocast universal
®
230 Casting System Installation Stand 1.9. 03 B 16
Comentarios a estos manuales