Diamond Systems Tritan Instrucciones de operaciones Pagina 11

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 90
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 10
autocast universal
®
230 Casting System Crowns and bridges Stand 1.9. 03 A 4
Preheating Crowns/Bridges
To achieve optimum expansion values and stable muffles,
we recommend 34 side-heated circulating air ovens with
program control (4 soaking stages) and temperature control
(5°C/41°F per min), e.g. Protherm circulating air preheating
oven (Ord.-No. 096-180-00).
There is a risk of cracking of the muffle if the oven does not
have sufficient insulation and the heating/cooling time is too
short. Do not fill the muffle space to capacity.
Overnight operation is recommended.
Holding times: 150°C / 302°F 90 minutes
250°C / 482°F 90 minutes
1000°C / 1832°F 60 minutes
Slow reduction of temperature to 430°C / 806°F = casting
temperature. Avoid temperature shock. Do not hold at final
temperature of 430°C / 806°F longer than 120 minutes.
Overall expansion
Test temperature 430°C
Setting expansion
Thermal expansion
Setting/thermal expansion
Expansion control for Crowns/Bridges
The adjustment of the expansion for the rematitan
®
plus
investment is exclusively done by dilution of the mixing
liquid. (see chart below).
Attention!
The mixing liquid is a concentrate which normally must be
diluted:
Recommendation for dilution:
Crowns and bridges:
60% = 6 parts of liquid + 4 parts of distilled water.
Conical and telescopic crowns:
70–100% = dilution related to the desired friction and ways
of processing.
Burnout schedule for rematitan
®
Plus investment
Heating rate: 5°C/41°F per min.
x = Holding times at:
150°C/302°F = 90 min.
250°C/482°F = 90 min.
1000°C/1832°F = 60 min.