autocast universal
®
230 Casting System Crowns and bridges Stand 1.9. 03 A 3
Mixing ratio: 250 g powder : 40 ml mixing liquid.
Mixing time in the vacuum mixer: 60 seconds.
Fill the muffle to the top with investment. Remove from the
vibrator immediately. Setting time: 40 minutes.
Pull off from the base/sprue former by twisting and grind
the side opposite the sprue, with the dry trimmer.
This promotes gas permeability of the investement in the
flow-direction of the titanium. Place the muffle with the
opening downwards in the cold oven.