autocast universal
®
230 Casting System Model casting Stand 1.9. 03 A 24
II Telescopic crowns
Preparation
1. The tooth arch in the silicone mould is first filled with
rematitan
®
Plus investment, which is mixed with diluted
rematitan
®
Plus crown/bridge mixing liquid (Ord.-No.
107-602-00).
Attention!
The mixing liquid is a concentrate which normally must
be diluted:
Recommendation for dilution:
Crowns and bridges:
60% = 6 parts of liquid + 4 parts of distilled water.
Conical and telescopic crowns:
70–100% = dilution related to the desired friction and
ways of processing.
2. Before the investment has set, the mould must be filled
with rematitan
®
Plus investment in the normal consistency
of 250 g : 40 ml (partial denture mixing liquid,
Ord.-No. 107-601-00).
3. The subsequent operating steps are the same as sections
4. to 11. of the instructions for conical crowns.
Amount of Titanium casting metal
required per casting
Minor combination work 31 g
Extensive combination work 36 g